NAVIGATIONAL IMPLANT PLACEMENT IN THE DELAYED PROTOCOL: AN EVIDENCE-BASED REVIEW
Keywords:
guided implant surgery; dynamic navigation; delayed implant placement; late placement; accuracy; CBCT; static computer-aided implant surgeryAbstract
Guided implant surgery transfers a digital, prosthetically driven plan to the patient with a static template, a dynamic navigation system, or a robot. In healed ridges (delayed or late placement, ITI types 3–4), the anatomy is stable and soft tissue has matured, which makes the digital plan reproducible. This review summarises the classification of placement timing, the biology of the healed ridge, the accuracy of static, dynamic and robotic systems, factors that change accuracy, clinical outcomes (survival, complications, marginal bone), and practical workflow and safety rules. Pooled data show mean deviations of about 1.0–1.2 mm at the entry point, 1.2–1.4 mm at the apex and 3–3.6° in angulation, which is why a safety margin of at least 2 mm from vital structures is recommended [8,15,16]. Long-term data specific to healed ridges are limited, and several conclusions below come from mixed populations, so they should be read with that in mind..
References
1. Hämmerle CH, Chen ST, Wilson TG Jr. Consensus statements and recommended clinical procedures regarding the placement of implants in extraction sockets. Int J Oral Maxillofac Implants. 2004;19(Suppl):26–28.
2. Chen ST, Buser D. Clinical and esthetic outcomes of implants placed in postextraction sites. Int J Oral Maxillofac Implants. 2009;24(Suppl):186–217.
3. Chen S, Buser D. Implants in post-extraction sites: a literature update. In: Buser D, Belser U, Wismeijer D, eds. ITI Treatment Guide, Vol. 3: Implants in Extraction Sockets. Berlin: Quintessence; 2008.
4. Gallucci GO, et al. Implant placement and loading protocols in partially edentulous patients: a systematic review. Clin Oral Implants Res. 2018;29(Suppl 16).
5. Araújo MG, Lindhe J. Dimensional ridge alterations following tooth extraction. An experimental study in the dog. J Clin Periodontol. 2005;32(2):212–218.
6. Araújo MG, Lindhe J. Ridge alterations following implant placement in fresh extraction sockets: an experimental study in the dog. J Clin Periodontol. 2005;32(6):645–652. doi:10.1111/j.1600-051X.2005.00726.x
7. Tan WL, Wong TL, Wong MC, Lang NP. A systematic review of post-extractional alveolar hard and soft tissue dimensional changes in humans. Clin Oral Implants Res. 2012;23(Suppl 5):1–21.
8. Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. The accuracy of static computer-aided implant surgery: a systematic review and meta-analysis. Clin Oral Implants Res. 2018;29(Suppl 16):416–435.
9. Wismeijer D, Joda T, Flügge T, et al. Group 5 ITI Consensus Report: digital technologies. Clin Oral Implants Res. 2018;29(Suppl 16):436–442. doi:10.1111/clr.13309
10. Jung RE, Schneider D, Ganeles J, Wismeijer D, Zwahlen M, Hämmerle CHF, Tahmaseb A. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants. 2009;24(Suppl):92–109.
11. Schneider D, Marquardt P, Zwahlen M, Jung RE. A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry. Clin Oral Implants Res. 2009;20(Suppl 4):73–86. doi:10.1111/j.1600-0501.2009.01788.x
12. Raico Gallardo YN, da Silva-Olivio IRT, Mukai E, Morimoto S, Sesma N, Cordaro L. Accuracy comparison of guided surgery for dental implants according to the tissue of support: a systematic review and meta-analysis. Clin Oral Implants Res. 2016 (online). doi:10.1111/clr.12841
13. Balaguer Martí JC, Canet López Á, Peñarrocha Diago M, Romeo Rubio M, Peñarrocha Diago M, García Mira B. Influence of splint support on the precision of static totally guided dental implant surgery: a systematic review and network meta-analysis. Int J Oral Maxillofac Implants. 2023;38(1):157–168. doi:10.11607/jomi.9796
14. Shi Y, Wang J, Ma C, et al. A systematic review of the accuracy of digital surgical guides for dental implantation. Int J Implant Dent. 2023. doi:10.1186/s40729-023-00507-w
15. Khaohoen A, et al. Accuracy of implant placement with computer-aided static, dynamic, and robot-assisted surgery: a systematic review and meta-analysis of clinical trials. BMC Oral Health. 2024. doi:10.1186/s12903-024-04033-y
16. Wei SM, Zhu Y, Wei JX, Zhang CN, Shi JY, Lai HC. Accuracy of dynamic navigation in implant surgery: a systematic review and meta-analysis. Clin Oral Implants Res. 2021;32(4):383–393. doi:10.1111/clr.13719
17. Jorba-García A, González-Barnadas A, Camps-Font O, Figueiredo R, Valmaseda-Castellón E. Accuracy assessment of dynamic computer-aided implant placement: a systematic review and meta-analysis. Clin Oral Investig. 2021;25(5):2479–2494.
18. Castro F, Pereira P, Falcão-Costa C, Falcão A, Fernandes JCH, Fernandes GVO, Rios JV. Comparison of the accuracy/precision among guided (static), manual, and dynamic navigation in dental implant surgery: a systematic review and meta-analysis. Oral Maxillofac Surg. 2025. doi:10.1007/s10006-025-01462-z
19. Abdelhay N, Prasad S, Gibson MP. Failure rates associated with guided versus non-guided dental implant placement: a systematic review and meta-analysis. BDJ Open. 2021;7:31. doi:10.1038/s41405-021-00086-1
20. Yogui FC, Verri FR, et al. Comparison between computer-guided and freehand dental implant placement surgery: a systematic review and meta-analysis. Int J Oral Maxillofac Surg. 2020 (online). doi:10.1016/j.ijom.2020.08.004
21. Gallucci G, Evans C, Tahmaseb A. Digital Workflows in Implant Dentistry. ITI Treatment Guide, Vol. 11. Wismeijer D, Barter S, Donos N, eds. Berlin: Quintessence.
22. Matvijenko K, Borusevičius R. Comparison of dynamic navigation systems in dental implantology: a systematic literature review of in vitro studies. Int J Oral Maxillofac Surg. 2025;54(7):647–656. doi:10.1016/j.ijom.2025.02.005
23. Jorba-García A, Figueiredo R, González-Barnadas A, Camps-Font O, Valmaseda-Castellón E. Accuracy and the role of experience in dynamic computer guided dental implant surgery: an in-vitro study. 2019 .
24. Comparing the clinical outcomes of guided and freehand dental implant surgery: an umbrella review of systematic reviews and meta-analyses. PMID 41206337.
25. Bone temperature variation using a 3D-printed surgical guide with internal irrigation. Appl Sci. 2021;11:2588. 25a. Heat generation in guided implant osteotomy: influence of irrigation route, bone structure, and measurement method: a comparative thermal analysis.
26. Thermal changes during guided flapless implant site preparation: a comparative study .
27. Gallucci GO, Hamilton A, Akhondi S, Pala K, Peña-Cardelles JF. Current state of evidence for implant placement and loading in partially edentulous patients: a systematic review .
28. Marquez Bautista N, Meniz-García C, López-Carriches C, Sánchez-Labrador L, Cortés-Bretón Brinkmann J, Madrigal Martínez-Pereda C. Accuracy of different systems of guided implant surgery and methods for quantification: a systematic review. Appl Sci. 2024;14(24):11479. doi:10.3390/app142411479
29. Walker-Finch K, Ucer C. Five-year survival rates for implants placed using digitally-designed static surgical guides: a systematic review. Br J Oral Maxillofac Surg. 2020;58(3):268–276. doi:10.1016/j.bjoms.2019.12.007
30. Methodologies for assessing the dimensional accuracy of computer-guided static implant surgery in clinical settings: a scoping review. Dent J (MDPI), vol. 14, no. 1, art. 43 (authors and year to confirm).
31. Accuracy of implant placement with robotic surgery, dynamic navigation, fully static guide and freehand surgery: a systematic review and network meta-analysis. Int J Oral Maxillofac Implants (preprint; authors and year to confirm).
32. Computer-assisted implant surgery: patients' experience and perspectives (white paper; authors and journal to confirm).
33. A 10-year follow-up study on clinical outcomes of dental implant rehabilitation using surgical guide. J Korean Assoc Oral Maxillofac Surg, vol. 50, no. 2 (authors and year to confirm).
34. A retrospective study of dynamic navigation system-assisted implant placement. BMC Oral Health. doi:10.1186/s12903-023-03481-2 (authors to confirm).
35. Clinical applications and effectiveness of guided implant surgery: a critical review based on randomized controlled trials. BMC Oral Health. doi:10.1186/s12903-017-0441-y (authors and year to confirm; not cited in the text above).
36. Computer-guided implant surgery. Consensus statements, 5th ITI Consensus Conference. ITI Academy consensus database, iti.org.